ISO 17278:2020

ISO 17278:2020 pdf free.Rubber, raw natural – Determination of the gel content of technically specified rubber (TSR)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at http://www.electropedia.org/
3.1 technically specified rubber TSR natural rubber obtained from the latex of Hevea brasiliensis (typically processed into block rubber), and having properties complying with the criteria for the grade concerned
4 Principle
A TSR sample is dissolved in toluene under specified conditions, and the gel content is calculated as the percentage mass fraction of the insoluble part of the rubber.
5 Reagent
Use only reagents of recognized analytical grade.
5.1 Toluene, analytical grade.
CAUTION — The solvent might evaporate from the flask or tube when it is handled. Therefore, handling this solvent should be done only when permitted and only in a well-ventilated appropriate place.5.2 Acetone, analytical grade.
6 Apparatus
6.1 Laboratory centrifuge, capable of rotating at a minimum of 14 000 r/min (revolutions per minute).
If the above speed cannot be attained a minimum speed of 8 000 r/min may be used with a longer running time (8.2.4).
NOTE When the centrifugal rotational frequency (rotational speed) is 14 000 r/min, the gravitational acceleration is 22 000g. When the centrifugal rotation speed is 8 000 r/min, the gravitational acceleration is 7 000g.
6.2 Screw-cap centrifuge tubes, with a minimum capacity of 30 cm3, capable of withstanding the centrifuge conditions and of being heated to a temperature greater than 110 °C.
6.3 Balance, capable of accurately weighing to ± 0,1 mg.
6.4 Laboratory oven, gravity convection type, capable of controlling the temperature to ± 10 °C.
6.5 Weighing container, i.e. an aluminium box or plate for weighing.
7 Conditions Laboratory conditions shall be controlled in accordance with ISO 23529.
8 Procedure
8.1 Number of test samples
Two test samples shall be taken in accordance with Clause 7 of ISO 2000:2014.
8.2 Procedure
8.2.1 Take a test sample from a bale without milling of mass calculated at the ratio of 0,1 g per 30 cm3 of toluene. NOTE When the volume of a centrifuge tube is 50 cm3, the volume of toluene is 30 cm3 (see 8.2.3), and the sample weight is 0,1 g.
8.2.2 Cut the test sample into approximately 1 mm3-sized pieces using clean scissors. Weigh the
prepared test pieces to the nearest 0,1 mg (m,). Place the pieces in a clean centrifuge tube (6.2), which has previously been heated at 100。C for 1 h and stored in a desiccator. .
8.2.3 Add toluene to the tube until it is 60 % full. Cap it and shake by hand for a few seconds. Then,
allow it to stand for 16 h to 20 h in dark conditions without stirring at (25土2)°C.
8.2.4 After this period, shake the tube up and down for 60 s to disperse the jelly-like precipitate on the bottom.
Before placing the tubes in the centrifuge machine, all tubes shall be filled up with fresh toluene, so that the volume of solution is the same in all tubes.
NOTE A centrifuge tube is usually filled up with solution to minimize the dead space created at the top of the tube because of the vacuum-pressured environment during rotation.
Place the tubes in the centrifuge machine and operate the machine at 14 000 r/min for 2 h.
If the rotating capacity of the centrifuge machine is below 14 000 r/min, operate the machine at 8 000 r/ minfor6h.
A set temperature of centrifuge is usually indicated in the operation manual for safety reasons. If not, it may be set to between 0 °C and 25 °C.
8.2.5 Remove the tube from the machine and pipette the liquid from the tube held at approximately
45°. Caution shall be taken to prevent pipetting the precipitate.
8.2.6 Add 1 ml to 3 ml of acetone to the precipitate so that it can be easily peeled from the bottom of the tube. Leave to stand for over 30 s and then pipette the liquid from the tube.
8.2.7 Peel off the precipitate remaining at the bottom of the tube with a spatula or a spatula-like stick and move it into the container (±S) which has been cleaned and weighed to the nearest 1 mg (m1). A limited amount of acetone may be used to rinse the spatula, if necessary.ISO 17278 pdf download.

Leave a Reply

Your email address will not be published. Required fields are marked *